EN
Urban power grid cables are laid deep underground with complex line operating conditions, and the volume of emergency fault repair tasks keeps increasing year by year. Traditional testing equipment is cumbersome to carry, scattered in operation and low in efficiency, which cannot satisfy the current grid’s requirements for flexible, rapid and high-efficiency operation and maintenance. Following the development trend of integrated and mobile power testing in the electric power industry, our company has launched multiple models of vehicle-mounted cable drums to match cable fault location vehicles.
These drums adopt a special vehicle-mounted integrated structure, with differentiated configurations adapting to different working distances and site conditions, and are compatible with various types of cable fault location equipment. Lightweight, firm and stable, tidy in storage and convenient for transfer, they effectively solve the problems of messy cable winding and complicated operation existing in traditional products. They simplify operation procedures, shorten emergency repair time, lower work intensity, greatly improve the efficiency of cable inspection and fault rush repair, and reduce losses caused by power outages.

MCR-3 Manual

MCR-2 Manual

MCR-1 Manual

MCR-1-E Manual








MCR-3 |
MCR-2 |
MCR-1 |
MCR-1-E |
|
Supplied Cables |
①HV cable
②Earthing cable
③AC Power Supply Cable
④F-U lead
⑤Custom HV interconnection cable(Drum-to-SWG)
⑥Custom AC interconnection cable(Drum-to-SWG)
|
①HV cable
②Earthing cable
③F-U lead
④Custom HV interconnection cable(Drum-to-SWG)
|
①HV cable
②F-U lead
|
①HV cable |
HV cable |
50m (Standard), 4mm², 60kV DC, OD 16mm |
50m (Standard), 4mm², 60kV DC, OD 16mm |
50m (Standard), 4mm², 60kV DC, OD 16mm |
25m (Standard), 4mm², 90kV DC, OD 14mm |
Earthing cable |
50m (Standard), 16mm², OD 8mm |
50m (Standard), 16mm², OD 8mm |
/ | / |
AC Power Supply Cable |
30m (Standard), 3x2.5mm², OD 10mm |
/ |
/ | / |
F-U lead |
10m (Standard), 1.5mm² |
10m (Standard), 1.5mm² |
10m (Standard), 1.5mm² |
/ |
|
Custom HV interconnection
cable (Drum-to-SWG)
|
3m (Standard), 4mm², 90kV DC, OD 14mm |
3m (Standard), 4mm², 90kV DC, OD 14mm |
3m (Standard), 4mm², 90kV DC, OD 14mm |
/ |
|
Custom AC interconnection
cable (Drum-to-SWG)
|
3m (Standard), 0.75mm² |
/ | / | / |
Motorization Level |
Manual |
Manual |
Manual | Manual |
Drum Withstand Voltage |
40kV DC |
40kV DC |
40kV DC |
90kV DC |
Dimensions |
37.3*37*108cm |
38.7*38*68cm |
37.3*37*45cm |
40*32*48cm |
Weight |
59kg |
45kg |
30kg |